Check if the hydraulic oil status is normal

Author: dkfilter Publish Time: Origin: Site

Check if the hydraulic oil status is normal

1. The first method

Hydraulic oil is too dirty - Hydraulic oil is dirty or too dirty, which may be due to chemical changes in the oil caused by long-term use; It may also be due to too many impurities causing physical changes. As long as the causes of these two changes are identified, corresponding measures can be taken. In the absence of necessary testing equipment and devices, a simple and practical method to determine whether hydraulic oil has undergone chemical or physical changes is to use filter paper detection. 

Take a sample of hydraulic oil, drop the oil onto filter paper, and observe the oil halo formed. If the layering and ring phenomenon of the oil halo is more obvious (the middle is dirty, and the edge is clearer), it indicates that the hydraulic oil has deteriorated and must be replaced with new oil; If the oil halo spreads evenly, it indicates that there are too many impurities in the hydraulic oil. The oil filter should be checked in a timely manner, the filter element should be replaced, and if necessary, new hydraulic oil should be replaced.


2. The second method

Hydraulic oil has impurities that appear turbid - there are three main types of impurities in hydraulic oil, namely solid impurities (debris, solid particles, solid impurities formed by hydraulic oil deterioration, etc.), liquid impurities (mainly water, followed by viscous impurities formed by hydraulic oil deterioration), and gaseous impurities (mainly air). If the hydraulic oil shows white turbidity, the possibility of solid impurities or liquid viscous impurities can be ruled out, and it can only be caused by water or air. 

Can sample and test hydraulic oil. Drop the oil sample onto a hot iron plate. If bubbles appear (water turns into steam at high temperatures to form bubbles), it can be determined that there is water in the hydraulic oil. Otherwise, it is air in the hydraulic oil. If there is water mixed in the hydraulic oil causing turbidity, let the hydraulic oil stand for a period of time, let the water sink to the bottom of the hydraulic oil tank, and then remove the water. But if the moisture content is too high and causes hydraulic oil emulsification, a new hydraulic oil needs to be replaced. If it is determined that the turbidity is caused by air mixed in the hydraulic oil, the hydraulic system pipeline should be checked for air leakage and the source of air mixing should be cut off.


3. The third method

Abnormal increase in hydraulic oil temperature - The fundamental reasons for the abnormal increase in hydraulic oil temperature are as follows: firstly, due to the low pressure setting value of the safety valve, most of the hydraulic oil flows back to the oil tank through the safety valve, resulting in a low efficiency of the hydraulic system. If the load is too large, a large part of the energy will be converted into thermal energy of the hydraulic oil, leading to a high temperature. The second reason is due to the poor cooling effect of the cooling system, which leads to high hydraulic oil temperature. The third reason is that the hydraulic oil circulates too frequently in the oil circuit (often caused by insufficient oil volume), resulting in difficulty in heat dissipation and temperature rise. 

Check if the hydraulic oil status is normal

Fault diagnosis should start from easy to difficult. First, check the oil level in the hydraulic oil tank. If the oil level in the tank is insufficient, it should be added to the standard level in a timely manner. Attention should be paid to using hydraulic oil of the same brand when adding, and it should also be filtered before use.